RWM
The technical details are the secret behind its perfection
- During smoke extraction, the RWM 57 conveys media up to 600 °C for 120 mi
- Temperatures up to +80 °C are approved for permanent ventilation
- Conveys flow rates of up to 37,000 m3/h at pressure of up to 1,000 Pa
- The air output is horizontal
- The casing and all components subject to strain are made of galvanised or coated sheet steel
- A variable range of motors offers flexible drive options
- The add-on motor is completely separate from the airflow
- The output opening is fitted with a protective grille
- A pipe connection in line with DIN 24155-2 is fitted on the suction side
- The connecting cable comes without a plug for ease of installation
- The RWM 57 is supplied with tested accessories for integration into the façade and connection to the duct system
- A specially designed system of electrical components including smoke detector switchgear, an optical smoke detector and a manual trigger button rounds off the range of accessories
RWM 57
- With an IEC-compliant motor
- Low rate up to 37,000 m³/h
- 600 °C – 120 min
- No. 0036 CPD RG 01 03